SPECIFICATIONS:
Pre-assembled booth unit shall be Model #75HC, 5'4" x 7'6" , as
manufactured by Par-Kut International, Inc., Harrison Township,
Michigan (586) 468-2947. Unit shall be furnished complete and ready
to set in place on the site and shall include the following:
QUALITY: Structure
shall be the product of a manufacturer with a minimum of 10 years
experience in the design and fabrication of portable steel buildings.
STRUCTURE: Unit
shall be all welded galvanized steel construction with 14 gauge
steel panels and tubing on the exterior and 18 gauge interior panels
and trim. Unit to be shipped completely assembled. Welded joints
ground smooth.
BASE AND FLOOR:
A.1 - 2" base height (used in conjunction with a curb cut or ramp).
Or, B.1 - no floor, perimeter bar base only, floor to be concrete
slab by others. When provided by PAR-KUT, floor surface shall be
12 gauge galvanized steel, 4-way diamond plate. Four anchor clips
provided to secure building. Anchor bolts and required installation
by others.
PAINT: All steel
surfaces shall be painted with rust inhibitive epoxy primer. All
exposed interior and exterior steel surfaces shall be painted with
one finish coat of industrial acrylic epoxy. Choice of single color
of paint as selected by owner from manufacturer's standards.
LIGHTING: Shielded
fluorescent fixture (68 watts total) mounted over counter. Wall
mounted on/off switch located 48" above the floor.
ELECTRICAL: Unit
complete with all wiring required for fluorescent light, duplex
outlet, heater and 100 amp capacity 12 circuit breaker box. Wiring
No.12 (min) copper enclosed in EMT including green ground wire.
Wiring meets or exceeds minimum provisions of National Electric
Code. All fittings, wiring devices and fixtures UL listed. Ready
for site connection by others. Provide three wire 240/120 bolt single
phase service.
HEATER: Electric
wall heater shall be 120 volt/1500 watt/5120 BTU, including fan
and wall mounted thermostat.
OPTIONAL AIR CONDITIONER:
Shall be 120 volt/13500 BTU, roof mount, with wall mounted thermostat.
DOOR: Shall be
36" wide swinging steel door with safety glazing, weather-stripping,
heavy duty ball bearing butts and lever handle lockset. Door located
in 5'4" wall opposite the shelf. (Owner responsible for ramp, if
required)
WINDOWS: Shall
be aluminum construction with specified glazing, locks and hardware
as required. Model #75HC to include one horizontal sliding cashier
window 2'10" above grade. Windows in long side opposite the cashier
window shall slide up for ventilation and will include insect screens.
GLAZING: Shall
be clear tempered safety glass 1/8" minimum thickness.
COUNTER: 14 gauge
painted steel, 25" deep, 32" above floor with 16" wide steel storage
drawer.
INSULATION: Walls
insulated with 2" rigid Fiberglass Board, R10. Roof structure fully
insulated R17.4.
ROOF/CANOPY:
Shall be 14 gauge galvanized steel, pitched for rainwater run-off.
Extension beyond side walls shall be 3". Provide forged steel eyebolt(s)
in roof for lifting by crane. Exterior booths include drain pipe.
Interior booths to have flat, no overhang roof and removable lift
ring when overhead clearance is a problem.
DESIGN LOADS:
PAR-KUT booths meet or exceed the following design loads: 50 PSF
live load, 30PSF wind load.
Par-Kut reserves
the right to improve these specifications without notice.
|