GENERAL: Preassembled shelter shall be Model 145BS as
manufactured by Par-Kut International, Inc.,
Harrison Twp., Michigan. Unit to be furnished complete and
ready for use at site and shall include the following:
STRUCTURE: Unit shall be all welded galvanized steel
construction with 14 gauge steel panels and tubing on the
exterior and 18 gauge interior panels and trim. Unit to be
shipped completely assembled. All welded joints ground smooth.
Inside ceiling height 7'-6".
BASE AND FLOOR: Base height shall be 4". Floor shall
be 12 gauge galvanized steel, diamond plate. Four anchor clips
provided to secure shelter. Anchor bolts and required
installation by others. Unit may be recessed into concrete
island for flush threshold height to meet handicap requirements.
PAINT: All steel surfaces shall be painted with rust
inhibitive epoxy primer. All exposed interior and exterior
steel surfaces shall be finish painted with one finish coat of
acrylic epoxy paint. Choice of single color of paint as
selected by owner/architect.
LIGHTING: Fluorescent light fixture(s) mounted on ceiling,
twin lamp, zero degree ballast with vandal resistant lens.
Lights controlled by roof mounted photo eye or tamper resistant
switch. Solar powered lights optional.
WIRING: All wiring copper No. 12 minimum, enclosed in
EMT to 100amp capacity rain tight lockable circuit breaker panel.
Fittings, wiring devices and fixtures UL listed. Ready for site
connection by others. Provided three wire 120 volt single phase
service. Factory installed electric system shall include UL
inspection label certifying compliance with NEC.
HEAT: Factory installed electric ceiling heater(s) shall
be 120 volt, 5120 BTU, fan forced type, with tamper resistant
thermostat. Two heaters thus.
DOORS: Shall be aluminum construction and include glass
and hardware, and shall be fully weather-stripped. Door(s)
shall be top suspended sliding type, with minimum 32" clear
opening.
WINDOWS: Shall be clear anodized aluminum construction
and include glass. Windows to be fixed, and glazed from 12"
above finish floor to ceiling with center horizontal safety
mullion. Optional finish: painted to match shelter color.
GLAZING: Door(s) and windows shall contain clear tempered
safety glass 1/4" min. thickness. Optional glazing: tinted glass
or unbreakable polycarbonate.
BENCH SEAT: Optional hardwood, recycled plastic or
aluminum bench seat and seat back bolted in place to rear
wall of shelter.
INSULATION: Heated units shall have a minimum of 2"
rigid fiberglass in insulated wall panels, R=10. Roof
structure fully insulated, R-17.4.
CANOPY/ROOF: Shall be 14 gauge galvanized steel.
Extension beyond side walls shall be 3". Fascia height
to be 12" to accommodate customer graphics, or factory
applied lettering. Roof pitched for drainage and has
downspout. Lifting ring provided on roof, allows for
lifting/relocation by crane.
DESIGN LOADS: Par-Kut shelters meet or exceed the
following design loads: 50PSF live load, 30PSF wind load.
DESIGN NOTE: First digits of model number are the
length, the last digit is the width of the unit. For
instance, Model 145BS measures 14' long by 5' wide.